A series of significant anomalies were noticed in the TEPCO reactor data in recent weeks. When these anomalies were cross referenced against recent large quakes near the plant a concerning pattern appeared. Radiation, temperature and pressure readings show
a disturbing trend that indicates that melted fuel may be relocating. This set of information shows that there are concerns about the integrity of the concrete buildings. With reports of steam coming out of cracks in the ground and high radiation levels being found outside the reactor buildings these could be indicators of such damage.
fukuleaks.org/web members have plotted the data and provided technical analysis below.
The data and analysis below comes from one of our members that goes by the screenname “Edano” (no relation to the PM)
Regarding anomalities in tepco data since july 31 during 2 earthquakes M6.x
referring to
1) tepco data:
http://www.tepco.co.jp/nu/fukushima-np/f1/images/csv_temp_data_1u-j.csv
http://www.tepco.co.jp/nu/fukushima-np/f1/images/csv_temp_data_2u-j.csv
http://www.tepco.co.jp/nu/fukushima-np/f1/images/csv_temp_data_3u-j.csv
http://www.tepco.co.jp/nu/fukushima-np/f1/images/csv_level_pr_data_1u-j.csv
http://www.tepco.co.jp/nu/fukushima-np/f1/images/csv_level_pr_data_2u-j.csv
http://www.tepco.co.jp/nu/fukushima-np/f1/images/csv_level_pr_data_3u-j.csv
2) data plots: –http://www.fukuleaks.org/reactors/graphs.html
3)earthquakes:– M6.4 July 31 3:54 (eq1)- M6.0 August 12 3:22 (eq2)
factual anomalities:
– #1:— pressure drop on eq1 drywell from 115 kPa to 110 kPa in 4 hours, core and torus pressure decrease– radiation spikes since eq1 drywell b in Sv/h:
— 7/31 17:00 356
— 8/3 5:00 336
— 8/3 11:00 351
— 8/3 17:00 353
— 8/3 23:00 355
— 8/4 5:00 355
— 8/4 17:00 263
— 8/5 5:00 365
— 8/5 11:00 371
— 8/7 11:00 275
— 8/7 17:00 296
— 8/9 5:00 306
— 8/10 5:00 356
— 8/12 5:30 360 ( => eq2 )
— 8/12 11:00 334
— 8/13 5:00 319
— 8/13 11:00 364
— 8/15 17:00 359
— before eq1, there were no readings over 300 Sv/h
(click on image to get a larger version)



– #2:– temperature drop in CRD (control rod device) housing top (orange bubbles in plot):
— from 121.0 centigrades (7/30 23:00) to 110.0 centigrades (7/31 5:00) exactly on eq1
— from 98.0 centigrades (8/11 23:00) to 87.0 centigrades (8/12 5:30) exactly on eq2
— pressure decreasing since eq1:
— from constantly 135 kPa before 7/30 23:00 to 120 kPa now core pressure a (eq1)
— from constantly 134.325 kPa (101.325 + (0.033* 1000)) before 7/30 5:00 to 120.325 kPa + (0.019 * 1000) now torus pressure (eq1)
— radiation rise and sudden drop in drywell b:
— eq1: radiation slowly rising from 14.1 Sv/h before 7/28 11:00 (eq1) to 15.7 Sv/h on 8/11 23:00 (before eq2)
— eq2: sudden drop from 15.7 Sv/h (8/11 23:00) to 0.00207 Sv/h (8/12 5:30) exactly eq2
— rapidly rising again after eq2: 0.00207 – 0.00218 – 0.832 – 1.35 – 1.8 – 2.18 – 2.5 – 2.81 – 3.07 – 3.31 – 3.53 – 3.75 – 3.95 – 4.15 – 4.32 –
4.47 – 4.61 – 4.74 Sv/h now
(click on image for larger view)



– #3:— temperature drop in main steam valve 2-86a (dark green bubble in plot):
— from 144.5 centigrades before eq1 over 106.0 centigrades (eq2) to 103.5 centigrades now
— water level core a drops:
— eq1: from constantly -1700 mm (7/30 17:00) to -1900 mm (8/1 5:00)
— eq2: from constantly -1700 mm (8/11 23:00) to -1800 mm now
— water level core b drops:
— eq1: sudden drop from constantly -2150 mm (7/30 23:00) to -2300 mm (7/31 11:00)
— eq2: from 2200 mm (8/11 23:00) to -2100 mm (8/12 11:00)
(click image for a larger view)



– tepco data usually provides remarks to explain unusual readings, like instrument failures, electricity blackouts, power switchings, gauge replacing, recalibrations, false readings, etc, in each last column, or in the lowest row. however, there are no remarks since july 23. so there are no technical explanations.
interpretations:
– the decribed pressure, temperature and water level drops during the two last earthquakes are consistent with the now reported, probably highly
radioactive “steams out of ground cracks”. the earthquakes may have cracked underground parts of all 3 reactors esp. #1 and #2. #3 did not lose
pressure. since nitrogen is injected into all 3 reactors, we would normally expect rising pressures.
– the desribed rad spikes in #1 drywell b are significantly higher since the last earthquakes. spikes never reached 300 Sv/h before. though the
instrument has been reported as failure, there seem to be radioactive masses moving around and showing recriticality.
– the most significant anomaly happened in #2 drywell b. the radiation rose since eq1 and dropped suddenly within 6 hours from 15.7 to 0.00207 Sv/h during eq2. the only rational explanation would be a movement of radioactive masses and a leaking of the masses away from the instrument. radioactive particles may have escaped through the cracks with the steam.
– there have been reported more radioactive leaks with readings over 10 Sv/h. #3 has no radiation readings over 3.7 Sv/h. #1 has low radiation
readings (~0.7 Sv/h) aside from drywell b (27-371 Sv/h). #2 readings are around 6 (torus b), 10 (drywell a) and 15 (drwell b before eq2) Sv/h.
– if there is a realease of steam with rad levels over 10 Sv/h, it can only stem from #1 drywell or #2 drywell and torus through cracks in the containment and ground fissures, since steam rising from the soil outside the reactors is reported.
– the described anomalies are unique in the latest history (since april/may) and arise concerns about the integrity of the concrete buildings.
This article would not be possible without the extensive efforts of the SimplyInfo research team
Join the conversation at chat.simplyinfo.org
© 2011-2023 SimplyInfo.org, Fukuleaks.org All Rights Reserved
Content cited, quoted etc. from other sources is under the respective rights of that content owner. If you are viewing this page on any website other than http://www.simplyinfo.org (or http://www.fukuleaks.org) it may be plagiarized, please let us know. If you wish to reproduce any of our content in full or in more than a phrase or quote, please contact us first to obtain permission.
Pingback: New 57 (Sv/h) Radiation Increase In Unit 1 After Aug 17 Quake Near Fukushima Daiichi | SimplyInfo
Pingback: Nuclear Expert Warns Unit 1 Fuel May Be Out Of The Reactor Building | SimplyInfo