The Condensate Storage Tanks At Fukushima Daiichi

There have been questions about the role the condensate storage tanks played in the early hours of the disaster at Fukushima Daiichi. Below is a compilation of our discussions and discoveries of these tanks, the roles they played and their current status.

“The condensate storage tanks consist of the four large white tanks in front of the turbine buildings on the oceanside. Their storage capacity ranges from 1,900 m3 at Unit 1 to 2,500 m3 at the other three units. The tanks were about two-thirds filled on March 11. The volume could have fed the RCIC pumps for roughly 19 hours. Once the water in the condensate storage tanks of Units 2 and 3 was running low, the operators had to switch the suction isolation valves to set the suction path to the suppression pool in the wet well (torus) of the primary containment as alternate source for the RCIC and HPCI systems. The switch appears to have accelerated the reactors’ demise. The suction isolation valves may have failed. ” (Peter Melzer’s synopsis of the early events)

Peter had mentioned long ago that the suction valves are known to fail in a post at his blog. These Terry brand RCIC turbine pumps (suction pumps) are known to fail. The NRC has cited inadequate control systems in these pumps. A portion of the pipe system involved in the suction pump is not as seismically resistant as other parts. The suppression pool (torus) itself has its own series of woes related to the disaster such as water hammer effect from acute blowdown, the ability of it to fill with non-condensable gasses and to be damaged by steam or hydrogen blasts. The ECCS lines at most reactors are filled with water in an attempt to avoid a water hammer effect.


Diagram to the left shows the location of the condensate storage tanks at Fukushima Daiichi

More on March 11th and the condensation tanks, the logs say that the tanks for units 3 and 4 were not exactly full:
CST (condensation tank) level 66.1 % (for 3) and (for 4) 76.4 and 77.2%, CST Level 75.2 % (Unit 1) and 67 % (Unit 2). on Mar. 11. Unit 2’s water should have lasted 16 hours if the water had been used for the RCIC alone.

It lasted about 12 hours instead, according to the NISA reports to the IAEA: “From 04:20 to 05:00, March 12, as water level of the Condensate Storage Tank (CST) decreased and also in order to control rising of the S/C water level, the water source for the RCIC was switched from the CST to the S/C for the RCIC to continue injecting water.” The problems mounted after that. The tanks may have been more or less intact. Attempting to provide cooling water from the suppression pool must have precipitated the demise of the ECCS.”

Unit 1’s tank is the smallest and was used by the core sprayer and the HPCI, due to the smaller tank did this hasten the speed of the meltdown at unit 1? There are also questions about the IC (isolation condenser), it is unclear if or what is the method for make up water if the IC boils dry. The ultimate heat sink, in this case the ocean, was lost to the plant by the tsunami. New water was only available when the fire department arrived and established sea water pumps.

“The water from the circulating water system enters the condenser in a waterbox. The level in the waterbox must be maintained above the level of the uppermost tubes, otherwise the condenser will not be efficient. Generally the colder the circulating water, the more efficient the plant is. Power plants become less efficient when either the condenser tubes are fouled, e.g. by mud, plugging, or accumulation of other materials that reduce the ability to transfer heat from the steam to the water.”
The condenser can increase the water temp by as much as 40 degrees Fahrenheit.

Both of these are monitoring/surveilance tasks in the handover journals from TEPCO.
Also mentioned by TEPCO are issues with these condensation tanks on March 11th.
11/03/2011 units 3-4
shift 1 condensate return tank LCV 52-20 gland leaking wiping implementation
shift 2 condensate storage tank LCV-52-20 ground bleeding – wiped
TEPCO handover journals

“At 2:55 on March 12, it was confirmed that water was continually being injected to the reactor through the RCIC. After 2:55 on the same day, as it was confirmed that the water level
of the condensate storage tank had decreased, the RCIC water source was switched from the condensate storage tank to the S/C in order to maintain the water level of the condensate
storage tank and to prevent the S/C water level from increasing, and water injection was continued.”  Link to METI document

The condensate tanks played a role in the emergency cooling attempts of the reactors,  the amount of water that was in them at the time of the disaster also played a role.


Diagram of operation billiard (aka: water whack-a-mole)

Records show that later on the condensate tanks became part of the “operation billiard” where TEPCO continuously moved contaminated water around the plant in an attempt to deal with all the contaminated water accumulating at the plant.

Some of the instances of this are documented like these:

“31 March 2011 http://www.kantei.go.jp
Regarding Unit 1, with respect to the reactor, parameters of the reactor of Unit 1 are relatively stable right now. Regarding the spent fuel pool, we are injecting pure water into the spent fuel pool of Unit 1. With respect to stagnant water, a part of the water in the turbine building was already pumped out into the hot well. Since the hot well became full, we plan to move the water in the hot well to the condensate storage tank. Before that, we will move the water in the condensate storage tank to the suppression pool surge tank. Water in the trench – a part of this water in the trench attached to Unit 1 was moved to the radioactive waste building to lower the surface by 1m.Press briefing at the Prime Minister’s Office for members of the foreign press
8 April 2011
Regarding stagnant water, we are transferring the water in the hot well to the condensate storage tank. We found the level of the surface of the water in the condensate storage tank has not been changed for two days. So we will add or change to one more pump. Regarding Unit 2, especially stagnant water, we are transferring the water in the hot well to the condensate storage tank. We will finish it by 8 or 9 April to prepare for the pumping up of stagnant water to the hot well. Regarding the highly irradiated water, which came from the crack on the outside wall of the pit, it was stopped, as I reported yesterday. We injected water glass and chemicals to strengthen the function of stopping the water. In the meantime, the surface of the water in the trench attached to Unit 2 went up by 2cm from last night to early morning, today. So, we have to be careful in watching this trend

Regarding Unit 3, the parameters of the reactor of Unit 3 are relatively stable. We will throw 70t of pure water to the spent fuel pool of Unit 3 this evening. Regarding stagnant water, we would like to transfer the water in the hot well to the condensate storage tank, but there may be some inflow to the hot well, and we are investigating the source of this inflow. ”

These condensate storage tanks have been used to store contaminated water from turbine buildings, http://www.tepco.co.jp
Draining water from underground floor of turbine buildings
-At 1:55 pm April 3rd, in Unit 1, water transfer from the condenser to the condensate storage tank was commenced.
-From 5:10 pm, April 2nd to 1:10 pm, April 9th, in Unit 2, water in the condenser was transferred to the condensate storage tank.
-On April 7th, we knocked holes in the external walls (including louvers) of turbine buildings at Units 2 to 4 in order to get the draining hoses through to the Central Environmental Facility.

So the tanks appear to have been somewhat operational later on, that they at least are holding water.

One thing that was perplexing is that if these tanks are a critical part of the emergency cooling systems why they are located in an unprotected area facing the sea front. These tanks are vulnerable to tsunami damage or sabotage. There is nothing protecting them. The suppression chamber (torus) is considered the “credited system” that would have the most durable piping systems, the condensate tank system is frequently not considered to be such and therefore doesn’t have the higher grade of piping and systems that is required of rector critical components. The condensate tank supplies the for HPCI and RCIC. The suppression chamber being the “credited system” is why the instrumentation to swap the suction to the suppression pool at low CST level or high suppression pool level are the only Tech Spec required components. The condensate tank is not considered a critical system, the pipes to the condensate tank are known to be a source of tritium leaks at nuclear power plants.

We did discover some foundation damage on the tanks at Fukushima Daiichi. The ground underneath had sunk in many places. This matches the nearby pavement that became wavy as the ground sank and bulged from the earthquake. This distant location also requires piping to run from the reactor building, through the turbine building and out to the tank outside in order to make the full path to the reactor systems. Each time piping goes through a building it increases the risk of pipes being damaged as different buildings move with an earthquake differently based on their construction. If these pipes are not the same class as critical reactor piping they are also more prone to damage. The condensate tank placement shows yet another weak link in reactor safety and plant security.

Images of the tanks post tsunami:

Unit 1 Condensate Tank
Unit 2 Condensate Tank
Unit 3 Condensate Tank
Unit 4 Condensate Tank
Unit 2 tank base with soil sunk at base.
Unit 3 tank base, soil sinking and water collection around tank

This article would not be possible without the extensive efforts of the SimplyInfo research team
Join the conversation at chat.simplyinfo.org

© 2011-2023 SimplyInfo.org, Fukuleaks.org All Rights Reserved Content cited, quoted etc. from other sources is under the respective rights of that content owner. If you are viewing this page on any website other than http://www.simplyinfo.org (or http://www.fukuleaks.org) it may be plagiarized, please let us know. If you wish to reproduce any of our content in full or in more than a phrase or quote, please contact us first to obtain permission.

Editor

Editor, SimplyInfo.org

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses Akismet to reduce spam. Learn how your comment data is processed.

%d bloggers like this: